GALAXY 3.3 BLACK

Coming soon

Shelter Light with Power Back-up and Advanced Dimming System (ADS), 4100 lm

RDL0013-3B

GALAXY 3.3 Black shelter light, 4100 lm; 230 V AC with built-in Li-ion 10.8 V 2600 mAh emergency back-up battery for up to 1 h after outage; Advanced Dimming System for stepless brightness adjustment from 1100 to 4100 lm; linear connection of up to 15 units in one circuit; IP66, IK10; black housing.
IP66<BR>RATING

IP66
RATING

IK10 RATING<BR><BR>

IK10 RATING

ADVANCED<BR>DIMMING<BR>SYSTEM

ADVANCED
DIMMING
SYSTEM

ON/OFF SWITCH<BR><BR>

ON/OFF SWITCH

POWER<BR>BACK-UP

POWER
BACK-UP

GALAXY 3.3 Black is a professional shelter light with emergency back-up power, built for industrial, rescue, medical, and military applications. Housed in a black casing, it features the Advanced Dimming System (ADS), enabling smooth brightness control from 1100 lm to 4100 lm. Its power back-up function provides up to 1 hour of operation after a 230 V AC power outage, supported by a built-in Li-ion 10.8 V 2600 mAh battery. The system supports a linear connection of up to 15 lights within a single power circuit. Its IP66- and IK10-rated housing provides protection against dust, water, and mechanical damage. Power cords are available separately (with an IP54 Schuko plug or an IP68 BALS Schuko plug).

Key Features of Galaxy 3.3 Black

Power Back-up

The standout feature of Galaxy 3.3 Black is its Power Back-up function, providing up to 1 hour of operation after a 230 V AC power outage. Emergency operation is supported by a built-in Li-ion 10.8 V 2600 mAh battery. This ensures illumination remains available in situations where a sudden loss of light could disrupt operations, slow response, or compromise safety.

Advanced Dimming System (ADS)

Galaxy 3.3 Black features the Advanced Dimming System (ADS), enabling smooth brightness adjustment from 1100 lm to 4100 lm. This allows light output to be matched precisely to the size of the work area, the nature of the task, and current operational requirements. The result is a system that can run at reduced brightness when lower output is sufficient or deliver full illumination when maximum coverage is needed.

Independent Control of Each Light

Each light in a linear setup is equipped with an individual switch and dimmer. This allows every unit to be switched on or off independently, with brightness adjusted separately for each one. The result is greater flexibility in managing the lighting layout, better alignment with real operating needs, and more efficient use of the system across the entire installation.

Linear Connection of up to 15 Lights

Galaxy 3.3 Black supports the linear connection of up to 15 lights within a single power circuit. This makes it possible to create longer lighting runs in shelters, temporary halls, and larger work areas where even light distribution and fast system expansion are essential.

Neutral White Light

The light emits at a 4000 K color temperature, delivering neutral, well-balanced illumination. This color temperature is especially well suited to technical, operational, medical, and temporary-use environments, supporting clear visibility and everyday working comfort.

Durable Housing and Long Service Life

The housing is made of aluminum and polycarbonate, combining strength with resistance to intensive use. IP66 and IK10 ratings confirm protection against dust, water, and mechanical damage, while the declared 80,000-hour lifespan reflects long-term, stable performance in demanding environments.

Mounting Accessories and Power Cords

The box includes mounting accessories only: 2 steel hanging wire ropes and 2 straps with carabiners. Power cords are available separately in two versions: with an IP54 Schuko plug or with an IP68 BALS Schuko plug, allowing the system to be configured to suit the installation type and operating environment.

Why Choose Galaxy 3.3 Black?

Galaxy 3.3 Black is built for environments where lighting must do more than deliver high output under normal conditions. Power Back-up, the Advanced Dimming System (ADS), independent control of each light, and linear connection of up to 15 units give users greater flexibility, stronger control over the lighting layout, and added operational security when power stability cannot be taken for granted. It is a shelter lighting solution developed for professional use wherever reliability matters most.

Applications of Galaxy 3.3 Black

Rescue and Medical Shelters

In rescue shelters, medical shelters, triage areas, and decontamination zones, Galaxy 3.3 Black provides not only the required level of illumination, but also continuity of lighting after a mains power failure. This is especially important wherever operations continue without interruption, often under time pressure and in changing conditions.

Temporary Halls, Technical Support Areas, and Service Zones

The model can be used in temporary halls, service zones, mobile workshops, and technical support areas. In these environments, both flexible system configuration and the ability to maintain lighting during emergency situations are critical.

Camps, Field Bases, and Temporary Infrastructure

Galaxy 3.3 Black is also well suited to command shelters, field bases, temporary storage areas, and facilities established for civil defense and civil protection operations. The system can be deployed in accommodation zones, population reception points, logistics areas, and other temporary facilities set up in response to emergencies, where dependable lighting and readiness after a power outage are especially important.

Technical Specifications - Galaxy 3.3 Black

POWER SUPPLY 230V AC / 50 Hz
POWER 8W - 30W
LIGHT OUTPUT 1100 lm - 4100 lm
OPERATING TEMPERATURE -35° C - +50° C
COLOR TEMPERATURE 4000 K
LIFESPAN 80 000 h
IP RATING IP66
HOUSING aluminum, polycarbonate
DIMENSIONS 350 x 103 x 100 mm (+ cord with power switch and dimmer 450 mm)
WEIGHT 1,87 kg
 

Accessories - Galaxy 3.3 Black

The set includes

RDL0013-3B: Shelter Light with Power Back-up, mounting accessories: 2 x hanging wire ropes, 2 x straps with carabiners - > up to 15 units in series.

Additional Accessories (sold separately)

  • RDL0112-P5B: 5 m Power Cord with IP54 Schuko plug
  • RDL0013-P5B: 5 m Power Cord with IP68 BALS Schuko plug
  • RDL0010-P2.5-2B: 2,5 m Interconnection Cord

SAFETY GUIDELINES

Safety Guidelines for Lighting Products

Safe Product Usage

  1. Use the product only as intended and follow the user manual instructions.
  2. Adhere to the recommended handling and maintenance guidelines to ensure proper operation.
  3. This product is not designed for use by children. Keep small components (e.g., batteries, accessories) out of their reach to prevent accidental ingestion or choking.

Operating and Storage Conditions

  1. Operate the product within a temperature range of -4°F to 104°F (-20°C to +40°C).
  2. Avoid exposing the product to direct sunlight, moisture, strong vibrations, solvents, chemical fumes, or other aggressive substances.
  3. Please do not use the product in explosive atmospheres unless it has appropriate certifications, such as ATEX.
  4. Please exercise caution when charging and connecting the device to the electrical network.
  5. When installing the device in a vehicle, use insulated terminals and protect the installation with a fuse.
  6. Activate the product with a transport lock during storage or transport.

Safe Handling of the Product

  1. Do not cover the product while in operation, as this may cause overheating and increase the fire risk.
  2. If the product overheats, turn it off or reduce the brightness mode to allow it to cool down.
  3. Avoid wearing headbands, wrist straps, cords, or other product components around the neck.
  4. Do not use the product as a tool, except for flashlights designed with an emergency glass-breaking function.

LEDs

  1. Never look directly into the light beam. LEDs may emit radiation classified as RG-2 according to IEC 62471, which can be harmful to the eyes.
  2. Do not direct the light onto the face, skin, or other sensitive surfaces. LED radiation in the 400–780 nm range can damage the retina or cause irreversible changes.
  3. Strobe or flashing light modes may trigger seizures in individuals with photosensitive epilepsy.

Batteries and Accumulators

  1. Do not disassemble, crush, puncture, heat, or incinerate batteries/accumulators.
  2. Do not use batteries and accumulators simultaneously or mix batteries of different brands or new and old ones. Use only batteries and accumulators compatible with the device.
  3. Charge accumulators only with dedicated chargers, within temperatures of 32°F to 104°F (0°C to +40°C).
  4. Never charge disposable batteries.
  5. Keep batteries and accumulators out of reach of children. If a battery, especially a button cell, is swallowed, seek medical attention immediately.
  6. Regularly recharge accumulators if the product is unused for extended periods (at least once every 3 months).
  7. For prolonged storage, remove batteries/accumulators to prevent leakage.

Weapon-Mounted Lighting

  1. Ensure the firearm is unloaded and the action is open when installing, cleaning, or maintaining the flashlight.
  2. Activate the flashlight only with the non-trigger hand while holding the gun securely with both hands.
  3. Take precautions to prevent accidental discharges.

Area Lighting

  1. Always deploy stabilizing supports when raising the lighting mast above 3.3 feet (1 meter).
  2. Do not direct the light source onto flammable surfaces during operation to avoid heat accumulation and fire hazards.

Disposal

  1. Dispose of lighting products, batteries, and accumulators by local electronic waste regulations.
  2. The crossed-out trash bin symbol indicates the obligation for separate disposal to prevent environmental pollution and facilitate material recovery.
  3. For products containing heavy metals: mercury (Hg), cadmium (Cd), lead (Pb), relevant chemical symbols are displayed below the bin symbol.
  4. You can return used devices and batteries free of charge at local collection points or stores with appropriate sales areas (per EU regulations).

Additional Precautions

  1. Products containing permanent magnets may pose risks to individuals with pacemakers. Always maintain a safe distance from such components.
  2. If the device is damaged, contact an authorized service center.
  3. Entrust repairs and maintenance only to authorized service personnel.