M-FIRE GUARDIAN XR

New

ATEX right-angle flashlight, 240 lm

PHH0231

The Atex angle flashlight, with a rechargeable battery and red light, is designed for Zone 0 and emergency operations.

ATEX certified for safety, it helps firefighters and rescue teams by penetrating smoke with its focused beam and enhancing visibility for team communication.
IP67<BR>RATING

IP67
RATING

1m IMPACT<BR>RESISTANCE

1m IMPACT
RESISTANCE

CLIP<BR><BR>

CLIP

BATTERY LEVEL<BR>INDICATOR

BATTERY LEVEL
INDICATOR

ATEX No: I M1 Ex ia I Ma<br>II 1G Ex ia IIC T4 Ga<br>CSANe 22ATEX1206X

ATEX No: I M1 Ex ia I Ma
II 1G Ex ia IIC T4 Ga
CSANe 22ATEX1206X

Key Features M-Fire Guardian XR

Dual Beam System

The flashlight offers two types of light beams and is equipped with two independent, intuitively placed switches for quick and precise mode selection.
  • A powerful, focused main beam (240 lumens, up to 205 m beam distance) surrounded by a wide peripheral halo – perfect for visibility in smoke, vapor, and fog.
  • The auxiliary red light, controlled by a separate switch, enhances visibility and safety during roadway operations and rescue zones. A pulsing mode further increases situational awareness for surrounding personnel.
Applications of the Red Light Mode:
  • Tactical identification for rescue teams, improving internal coordination.
  • Prevents blinding of pilots at temporary medical helicopter landing zones.
  • Supports firefighting teams in road accident scenarios.
  • Allows firefighters or rescue workers to direct traffic safely at accident scenes, improving motorist awareness and reducing the risk of secondary collisions.
The intuitive switch layout ensures that the controls can be easily located by touch alone, even in complete darkness.

Power & Charging System

The flashlight is powered by a 2600 mAh Li-Ion rechargeable battery, providing 6 hours of continuous runtime in High mode (240 lumens). Up to 224 hours of operation in Survival mode Charging is conducted via a dedicated docking station, compatible with AC power supply (230V AC) and vehicle power sources (12V/24V) Charging Convenience for Field Operations:
  • Charging directly in a vehicle eliminates the need for a power inverter, making it ideal for emergency responders and field professionals.
  • The charging cradle features an LED charge level indicator that changes from red to green to signal charging progress.
  • A single-handed release mechanism allows for quick deployment, a critical advantage in fast-paced and demanding environments.
Battery Status Monitoring
  • The four-stage battery level indicator, placed in an obvious position, allows users to monitor power levels effortlessly, even when the flashlight is attached to gear or clothing.
  • This practical solution enhances workplace safety by preventing unexpected power loss during critical operations.

ATEX Certification – Explosion-Proof Design

The M-Fire Guardian XR meets ATEX certification standards for Zone 0 explosive atmospheres, making it an essential tool for professionals working in high-risk environments where even the smallest spark could cause catastrophic consequences. Certified Safety for Hazardous Work Environments It is designed to prevent ignition in explosive gas mixtures, making it safe for use in oil, gas, and chemical industries, as well as by firefighting teams. The compliance with strict ATEX safety requirements makes it a top choice for hazardous work sites requiring non-sparking equipment.

Ergonomic & Durable Construction

  • Rubberized, textured grip provides a secure hold, minimizing the risk of accidental drops.
  • The reinforced rubber coating absorbs impact, increasing resistance to mechanical damage from falls and collisions.
  • Low-profile, lightweight design (305 g) minimizes snagging risks, ensuring ease of movement in tight spaces.
  • The heavy-duty clip allows for hands-free operation, making it ideal for firefighters, rescue teams, and industrial professionals.
  • Balanced mounting system, developed in collaboration with firefighters, prevents tilting, keeping the flashlight upright and stable during action.

Water & Dust Resistance – Built for Harsh Environments

  • IP67-rated for complete dust protection and water resistance up to 1 meter for 30 minutes.
  • Seamless, easy-to-clean housing prevents dust and dirt accumulation, ensuring long-term durability.
  • Designed for field conditions, allowing easy maintenance after exposure to mud, dust, and contaminants.

Why Choose the Mactronic M-Fire Guardian XR?

Professionals working in hazardous environments face critical challenges that require reliable, high-performance tools. The Mactronic M-Fire Guardian XR is designed to overcome these challenges, ensuring safety, efficiency, and durability in the most demanding conditions.

Applications M-Fire Guardian XR

Rescue & Emergency Services

The M-Fire Guardian XR is essential for rescue teams operating in high-risk explosive environments. Its powerful, focused beam penetrates heavy smoke, aiding evacuations and hazard identification. The auxiliary red light improves rescuer visibility in traffic, which is crucial during operations in challenging terrains.

Oil & Gas Industry

For workers on drilling platforms, refineries, and transmission stations, the M-Fire Guardian XR provides safety through ATEX certification and durability essential for harsh work conditions. Its dust and water resistance make it indispensable in areas prone to hazardous substance leaks.

Chemical & Petrochemical Industry

The M-Fire Guardian XR offers reliability with advanced anti-sparking protection in facilities that handle and store hazardous chemicals. Its ergonomic design and long runtime make it a trusted tool for professionals requiring precise lighting in demanding environments.

Technical Specifications M-Fire Guardian XR

ANSI FL1 standard
POWER SUPPLY Li-Ion 3.6V 2600 mAh rechargeable battery
CHARGING TIME 4 h
LIGHT OUTPUT RUN TIME BEAM DISTANCE PEAK BEAM INTENSITY
SPOT HIGH 240 lm 6 h 205 m 10 350 cd
SPOT MEDIUM 120 lm 12 h 20 min 145 m 5150 cd
SPOT LOW 70 lm 20 h 45 min 115 m 3170 cd
SPOT SURVIVAL 6 lm 224 h 33 m 280 cd
SPOT FLASHING - 12 h 15 min - -
FLOOD CONSTANT RED 13 lm 27 h 45 min - -
FLOOD FLASHING RED - 56 h 20 min - -
SPOT + FLOOD RED 240 lm 5 h 30 min - -
ATEX No. I M1 Ex ia I Ma, II 1G Ex ia IIC T4 Ga, CSANe 22ATEX1206X
IP RATING IP67
IMPACT RESISTANCE 1 m
DIMENSIONS 177 x 64 x 67 mm
WEIGHT 305 g
 

Accessories M-Fire Guardian XR

The Set Includes

charging base, 230V AC charger, 12V/24V DC car charger (PHH0231),
charging base, 12V/24V DC car charger (PHH0232),
flashlight only (PHH0234)

SAFETY GUIDELINES

Safety Guidelines for Lighting Products

Safe Product Usage

  1. Use the product only as intended and follow the user manual instructions.
  2. Adhere to the recommended handling and maintenance guidelines to ensure proper operation.
  3. This product is not designed for use by children. Keep small components (e.g., batteries, accessories) out of their reach to prevent accidental ingestion or choking.

Operating and Storage Conditions

  1. Operate the product within a temperature range of -4°F to 104°F (-20°C to +40°C).
  2. Avoid exposing the product to direct sunlight, moisture, strong vibrations, solvents, chemical fumes, or other aggressive substances.
  3. Please do not use the product in explosive atmospheres unless it has appropriate certifications, such as ATEX.
  4. Please exercise caution when charging and connecting the device to the electrical network.
  5. When installing the device in a vehicle, use insulated terminals and protect the installation with a fuse.
  6. Activate the product with a transport lock during storage or transport.

Safe Handling of the Product

  1. Do not cover the product while in operation, as this may cause overheating and increase the fire risk.
  2. If the product overheats, turn it off or reduce the brightness mode to allow it to cool down.
  3. Avoid wearing headbands, wrist straps, cords, or other product components around the neck.
  4. Do not use the product as a tool, except for flashlights designed with an emergency glass-breaking function.

LEDs

  1. Never look directly into the light beam. LEDs may emit radiation classified as RG-2 according to IEC 62471, which can be harmful to the eyes.
  2. Do not direct the light onto the face, skin, or other sensitive surfaces. LED radiation in the 400–780 nm range can damage the retina or cause irreversible changes.
  3. Strobe or flashing light modes may trigger seizures in individuals with photosensitive epilepsy.

Batteries and Accumulators

  1. Do not disassemble, crush, puncture, heat, or incinerate batteries/accumulators.
  2. Do not use batteries and accumulators simultaneously or mix batteries of different brands or new and old ones. Use only batteries and accumulators compatible with the device.
  3. Charge accumulators only with dedicated chargers, within temperatures of 32°F to 104°F (0°C to +40°C).
  4. Never charge disposable batteries.
  5. Keep batteries and accumulators out of reach of children. If a battery, especially a button cell, is swallowed, seek medical attention immediately.
  6. Regularly recharge accumulators if the product is unused for extended periods (at least once every 3 months).
  7. For prolonged storage, remove batteries/accumulators to prevent leakage.

Weapon-Mounted Lighting

  1. Ensure the firearm is unloaded and the action is open when installing, cleaning, or maintaining the flashlight.
  2. Activate the flashlight only with the non-trigger hand while holding the gun securely with both hands.
  3. Take precautions to prevent accidental discharges.

Area Lighting

  1. Always deploy stabilizing supports when raising the lighting mast above 3.3 feet (1 meter).
  2. Do not direct the light source onto flammable surfaces during operation to avoid heat accumulation and fire hazards.

Disposal

  1. Dispose of lighting products, batteries, and accumulators by local electronic waste regulations.
  2. The crossed-out trash bin symbol indicates the obligation for separate disposal to prevent environmental pollution and facilitate material recovery.
  3. For products containing heavy metals: mercury (Hg), cadmium (Cd), lead (Pb), relevant chemical symbols are displayed below the bin symbol.
  4. You can return used devices and batteries free of charge at local collection points or stores with appropriate sales areas (per EU regulations).

Additional Precautions

  1. Products containing permanent magnets may pose risks to individuals with pacemakers. Always maintain a safe distance from such components.
  2. If the device is damaged, contact an authorized service center.
  3. Entrust repairs and maintenance only to authorized service personnel.